Electrocardiograph-12 Channel

Model No. DG3016
Electrocardiograph-12 Channel

Features:

  • High resolution 8 inch color TFT with touch screen
  • Suitable for clinics, hospitals and outdoor camps
  • On screen display of 3/6/12- lead ECG with interpretation
  • Compact light weight and portable with carry handle
  • Lead-off and printer paper out indication
  • LED indicators for charging and AC/DC operation
  • In-built thermal printer with auto and manual mode
  • Digital filters to eliminate baseline drift, AC and EMG interface
  • Isolation protection against defibrillation
  • Soft touch alphanumeric and on screen virtual pop-up keyboard for data input
ECG
  • A/D Resolution : 24 Bit
  • Lead Selection : Standard 12 Leads
  • Notch Filter : 50/60 Hz
  • Noise Level : ≤12µVp-p
  • Acquisition : Auto/Manual
  • Memory : 1000 patients
  • Input impedance : ≥50M ohm(10Hz)
  • Frequency Response : 0.05-150Hz
  • CMRR : > 60 dB,> 100 dB
  • Time Constant : ≥3.2 sec
  • Sensitivity : 2.5, 5, 10, 20, 40mm/mV
  • Measurement : HR, P-R interval, P Duration, QRS Duration, T Duration,
                                Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5) amplitude,
                                S(V1) amplitude, R(V5)+S(V1) Amplitude
Display
  • Display Format : Twelve Channel
  • Graphics Display : 800 X 600 pixels TFT touch Screen (Color)
  • Display Size : 8 inch
  • On screen display : 3/6/12lead ECG, HR value, print mode, sensitivity,
                                         Paper speed, filter, time, battery indication, background grid
                                       Lines, measure data and interpretation
Recording & Printing
  • Recorder  : Thermal Printer
  • Paper Speed : 25, 50 mm/sec (Auto/Rhythm)
                                5, 6.25, 10, 12.5, 25 and 50 mm/sec (Manual)
  • Recording Paper : Thermo Sensitive 210 mm X 20m(Rolled)
  • Printing Labels : Patient Information Template, Leads,
  • Calibration, Print Speed, Filter, Sensitivity
  • Print-out Format : Auto and Manual Mode
Power Supply
  • Line Power supply : 110-240v, 50Hz ± 10%
  • Power Supply Operation : AC/DC with On/Off line Battery Charging
  • Battery : 14.8V / 3700 mAH, Li-ion rechargeable
  • Battery backup : 10 hrs standby time,
                                   3 hrs continuous print,
                                   300 ECG wave form recording
  • Input Power :  ≤ 150 VA
General
  • Data input : Touch screen and Function buttons
  • Communication Interface : USB
  • Degree of Protection : Type CF
Environmental Conditions
Operation
  • Temperature : 5°C to 40°C
  • Humidity            ≤ 80% non-condensing
  • Atmospheric pressure : 700 to 1060 hPa
Storage
Temperature : 1°C to 50°C
Humidity : ≤ 93% non-condensing
Atmospheric pressure : 500 to 1060 hPa

Request Quote Leave Message